Input: Accelerometer, 100mV/g
Accel excitation: 4mA ±2% at 24VDC to Input connection
Output: 4-20mA current loop output, into 0-600 ohms load resistance
Full scale output: Two inches/second peak velocity results in 20mA output
Zero signal output: Zero acceleration results
in 4mA output
Calibration level: 0.14VRMS input (1.4g RMS)
at 60.14Hz results in fullscale 20mA output
Frequency range: 5Hz to 2000Hz filtering, or customer specified range
Accel signal output: Buffered accelerometer
signal on separate BNC
Sensor fault alarm: Red LED indicates open
or shorted accelerometer and reduces 4-20mA output to below 2ma
Output fault alarm: Red LED indicates open condition in 4-20mA output wiring
Power: 115VAC 50/60Hz to attached linecord,
with power-on LED and internal fuse
|