MODEL 144 ACCELEROMETER
CONDITIONER
features
- 3 output modes
- Displacement output at discrete frequency
- 3 1/2 digit DPM readout
- Relay trip protection
Description
The Model 144 is a compact vibration monitoring system, with two single-channel
modules mounted in an 8" x 12" x 6" carrying case. Constant current
excitation is provided for an accelerometer charge converter, whose
signal is tightly filtered and monitored for exceeding a front-panel-set
level. If the level is exceeded, relay contacts complete an external
alarm circuit. A 4-20mA output also transmits the vibration level to
other continuous monitoring equipment.
Specifications
Input signal: Voltage output from accelerometer's charge
converter
Excitation: 4mADC constant current to charge converter; 24VDC
compliance
Input sensitivity: Typically 50mV/g
Gain: Front panel switch selects pre-filter gains of 0.1,
1, or 10, with locking 10-turn scale adjustment pot for overall range
of 0.1 to 200
Bandpass filter: Sharply tuned twin-tee filter at 120Hz (factory
adjustable from 40Hz to 5kHz)
AC output: Acceleration signal, gained and 120Hz filtered
(0-7VRMS max)
DC output: Jumper-selectable RMS/DC output (0-7VDC) or 4-20mA
version of RMS/DC voltage
Display: 3 1/2 digit LED meter indicates RMS/DC output
Alarm level: Settable by front panel trimpot from 0.1-10VRMS
Alarm output: Front panel LED and one nonlatching form C
(SPDT) relay contact operates on alarm condition
Power: Unregulated ±24V and +10V from rack-mounted
supply
Carrying case: 2 module desktop case, Model
4017-107