MODEL 144 ACCELEROMETER CONDITIONER |
Description The Model 144 is a compact vibration monitoring system with two single-channel modules mounted in a 6”H x 8”W x 12”D carry case. Constant current excitation is provided |
|
Specifications
Input signal: Voltage output from accelerometer's charge converter Excitation: 4mADC constant current to charge converter; 24VDC compliance Input sensitivity: Typically 50mV/g Gain: Front panel switch selects pre-filter gains of 0.1, 1, or 10, with locking 10-turn scale adjustment pot for overall range of 0.1 to 200 Bandpass filter: Sharply tuned twin-tee filter at 120Hz (factory adjustable from 40Hz to 5kHz) AC output: Acceleration signal, gained and 120Hz filtered (0-7VRMS max) DC output: Jumper-selectable RMS/DC output (0-7VDC) or 4-20mA version of RMS/DC voltage Display: 3 1/2 digit LED meter indicates RMS/DC output Alarm level: Settable by front panel trimpot from 0.1-10VRMS Alarm output: Front panel LED and one nonlatching form C (SPDT) relay contact operates on alarm condition Power: Unregulated ±24V and +10V from rack-mounted supply Carrying case: Two-module desktop case, Model 4017-107 |