MODEL FL646 THERMOCOUPLE ISOLATION AMPLIFIER
Description The Model FL646 Thermocouple Isolation Amplifier conditions a millivolt input from a thermocouple temperature probe. The input is isolated from the output by up to 1000VDC. The unit is mechanically and electrically compatible with Encore's other Flexi-line DIN-rail mounted instrumentation.
Specifications Input: Thermocouple or other millivolt signal, up to ±40mVDC Cold Junction Compensation: FL646-001: None; FL646-002: factory set for Type E, J, K, T, R, or S thermocouples Input Isolation: ±1000VDC Gain: 250, ±1% Filter: Three-pole active lowpass filter at 3Hz Output: 0 to ±10VDC, at 5mA max 4-20mA Output: Optionally available; tracks DC voltage output signal
Mechanical: 2.9" x 3.1" x 0.9" plastic enclosure; mounts on standard 35mm DIN-rail Power: Unregulated 18-30VDC at 25mA |
|