Description The Model FL645 RTD Isolation Amplifier conditions a resistance input from an RTD temperature probe. RTD resistance varies with temperature, producing a DC output voltage from the FL645. The input is isolated from the output by up to 1000VDC. The unit is mechanically and electrically compatible with Encore's other FlexiLine DIN-rail mounted instrumentation. |
![]() |
Specifications
Input: Resistance from RTD, 100 to 300 ohms
Input isolation: ±1000VDC
Filter: Three-pole active lowpass filter at 3Hz
Output: -5VDC for shorted input 0VDC for 100 ohms 10VDC for 300 ohms
Connections: Power and Output Six wireclamp screw terminals accept wire sizes from 24-14 gauge Input Removable 4-position wireclamp screw terminals accept wire sizes from 24-14 gauge Mechanical: 2.9" x 3.1" x 0.9" plastic enclosure; mounts on standard 35mm DIN rail
Power: Unregulated 18-30VDC at 30mA